Heinrichs Messtechnik GmbH • Robert-Perthel-Straße 9 • 50739 Köln • Tel.: +49 (221) 49708-0 • info@heinrichs.eu
Resistance temperature meter
- Measuring range: -80 …+600 °C
- Pt100 sensor class A or class B
- Output: Resistance or analog 4-20 mA
- Option: Head transmitter with HART® protocol or Profibus®/ Fieldbus, display
- for ATEX applications, type of protection Exd
Resistance thermometers for liquids, solids and gases.
The device is available as Pt100 – single or Pt100 double sensor in class A or B executed.
2 versions are available – head form B for Ex ia and head form XD as Ex d version
Available versions:
- Version Ex ia or Ex d
- With ceramic connection base (without converter)
- With transmitter
- With transmitter and LCD display
Applications
Measurement and monitoring of temperature of almost all liquids and light solids in air-conditioning and refrigeration technology, in heating and furnace, machine and apparatus engineering as well as in the chemical industry.
Installation in almost all tanks, silos or storage vessels as well as in pipelines.
Technical data
Accuracy
Pt 100 class A or B according IEC 751
Prozcess connections
- Flanges according DIN / ANSI
- Weld-in sleeve
- External thread
Wetted parts
- Stainless steel 1.4404 (316L) (special material on request)
Measuring range
- -30….+550 °C
- -80…+600 °C
Operating pressure
- max. 250 bar – dependent on the protective sleeve
Electrical data
- Output: resistance value, 2-, 3- or 4-wire
- Output: 4…20 mA,
- Supply voltage: 8..35 VDC with HART; 9…32 VDC with PROFIBUS / FIELDBUS FOUNDATION
Protection class
IP 54…IP 68
Certificates and approval
ATEX – Ex ia or Ex d
Communication
4-20 mA, Hart®, PROFIBUS / FIELDBUS FOUNDATION