Type TMU

Coriolis mass flow meter 2nd Generation

TMU-018-U-Profil-2zoll-Cl.242.png: Coriolis mass flow meter 2nd Generation
  • Size up to DN80
  • Measuring range 60…80.000 kg/h
  • Full welded stainless steel housing 1.4301/304L.
  • Measuring accuracy:0.1%
  • Integrated heating jacket (optionally)
  • DNV Approval
TMU 2nd Gen – Precision in One Flow

The TMU-2nd Generation Coriolis Mass Flow Meter is thoughtfully built to provide exceptional precision and reliability in measuring a diverse range of flow rates for a variety of industrial applications. With a capacity to handle flow rates ranging from 60 kg/h to 80,000 kg/h, this meter is ideal for activities that require accurate, consistent, and dependable observations. Precise results are guaranteed under the most difficult circumstances thanks to the combination of its sturdy design and cutting-edge measuring technology. The TMU-2nd Generation guarantees the accuracy and dependability required for maximum operating efficiency and product quality, whether working with liquids or gases.

Core Features

  • Precision Measurement
    Attains a measurement precision of 0.1%, guaranteeing exact identification of even the slightest changes in flow rate.
  • Durable Build
    The stainless-steel housing (1.4301/304L) is fully welded to provide superior durability and resistance to extreme environments.
  • Wide Temperature Range
    It functions optimally across a wide range of temperatures, making it appropriate for diverse industrial settings.
  • Enhanced Communication Choices
    Enables the integration of current control systems by supporting several communication protocols such as PROFIBUS, FIELDBUS, MODBUS, and HART®.

→ Downloads

High Flow Capacity

The TMU-2nd Generation is deliberately engineered to specifically meet the requirements of high-flow industrial processes. It smoothly combines with piping systems up to DN80, offering flexibility and compatibility with a diverse range of industrial configurations. This feature guarantees that the meter satisfies the stringent requirements of industries like oil and gas, chemical processing, and petrochemical manufacture. In these industries, it is crucial to maintain high flow rates to assure process efficiency and integrity.

Robust and Reliable Design

The high-quality materials used in the construction of the TMU-2nd Generation Coriolis Mass Flow Meter provide remarkable resistance against corrosion, abrasion, and chemical damage. The durable construction guarantees enduring functionality and dependability, even in the most severe circumstances. The combination of robust materials and cutting-edge engineering improves the meter’s adaptability and dependability across many industrial applications.

Wide Temperature Operating Range

The TMU-2nd Generation operates effectively within a broad temperature range, making it adaptable to both extremely cold and high-temperature environments. This flexibility ensures accurate and reliable flow measurements regardless of temperature fluctuations, vital for maintaining process stability and product quality in diverse industrial settings.

Optional Heating Jacket

An optional heating jacket is available to maintain fluid temperatures and prevent solidification in cold environments. This feature significantly enhances the meter’s performance in low-temperature conditions, ensuring uninterrupted and reliable flow measurement. The heating jacket is particularly beneficial for processes involving viscous fluids or chemicals prone to solidification, maintaining fluid consistency and measurement accuracy even at fluctuating temperatures.

Send a request

Applications

The TMU-2nd Generation Coriolis Mass Flow Meter is designed to excel in a wide range of industries, providing critical measurement solutions for:

  • Oil and Gas Loading Stations: Guarantees accurate measurement of substantial quantities, which is essential for effective and secure loading operations.
  • Pipeline Systems (on-shore and off-shore): Appropriate for incorporation into large-scale pipeline systems, guaranteeing precise and reliable flow measurement.
  • Industrial Processing Plants: Ideal for various industrial processes that require handling and measuring high flow rates of liquids or gases, ensuring accuracy even in challenging conditions.

Special features

Key Highlights

  • Compatible with DN80 piping systems.
  • Withstands pressures up to 40 bar.
  • Developed using advanced simulation methods (CSM, FEM, CFD, CEM, FSI, and TFSI).
  • Tantalum components resist acids and aggressive fluids.
  • Suitable for pharmaceuticals and food products.
  • Ensures long lifespan and low maintenance.
  • Simplified setup, configuration, and maintenance with digital interfaces.

Comprehensive Certifications:

  • ATEX / IECEx: Certified for use in explosive atmospheres.
  • CSA (North America): Meets North American safety and performance standards.
  • NEPSI (China): Complies with Chinese safety regulations.
  • CS (Korea): Certified for use in Korean industrial applications.
  • EAC (Eurasian Union): Ensures compliance with Eurasian standards.
  • Marine Certifications: Approved by DNV for marine applications.

Explore the TMU-2nd Generation Coriolis Mass Flow Meter and experience the precision, reliability, and advanced technology that sets Heinrichs apart in the field of industrial measurement solutions.

Technical data

Sensor

  • Sensor: TMU
  • System: Coriolis
  • Measuring range: 60…80.000 kg/h
  • Accuracy:
    • Gas: ±0.5 % of actual flowrate ± ZP stability
    • Liquids: ±0.1 % of actual flowrate ± ZP stability
  • Wetted parts:
    • 1.4571 (316 TI)
    • Hastelloy C-22
    • Tantalum
  • Sensor enclosure: 1.4301 (304L)
  • Process connections:
    • Flanges acc. DIN EN 1092-1, ASME B16.5-2003, JIS B2200-2004
    • Thread: G, NPT
    • others on request
  • ATEX / IECEx Approval: II 1/2G Ex ia IIC T2…T6 Ga/Gb
  • Max. Process pressure: PN40. High pressure design on request.
  • Process temperature: -40…+260°C
  • Ambient temperature: -40…+60°C
  • Ingress protection: IP67 (EN60529)

Transmitter

  • Model: UMC4
  • Power supply: 19…36 VDC
  • Signal outputs: (galvanically separated)
    • Analogue: 2 x 4-20 mA HART®, passive (Standard or Ex „i“)
    • Pulse output (or Frequency output): passive, via optocoupler as Frequency output max. 1 KHz
    • Status output: passive, via optocoupler
      option: second pulse output 90° phase shifted
  • Ambient temperature: -40…+55°C
  • Ingress protection: IP68 (EN 60529)
  • ATEX Approval:
    • Field housing: II 3(1)G Ex ec [ia Ga] IIC T6..T3 Gc
      (protection class terminal compartment Ex d)
    • Rack Mount Housing: II 3G Ex ec [ia Ga] IIC T3-T4 Gc
      (Rack Mount), Ambient up to 60°C
  • CE-Marking:
    • 2014/30/EU (EMC)
    • 2014/34/EU (ATEX)
    • 2014/35/EU (LVD)
    • 2014/68/EU (PED)
  • Communication: HART®

Certificates and Approvals

  • ATEX / IECEx
    • DMT 01 ATEX E 149 X
      II 1/2G Ex ia IIC T6 … T2 Ga/Gb
    • IECEx BVS 11.0084X
      Ex ia IIC T6 … T2 Ga/Gb
      (Approval for Zone 0 inside flow tubes)
  • CSA (North America)
    • 70171067
      Class I, Div. 1 and Div. 2 Gr. ABCD
      Ex ia IIC T5…T2 Ga
      Class I, Zone 0, AEx ia IIC T5…T2 Ga
  • NEPSI (China)
    • Remote: GYJ22.1873X
      Ex ia II C T2…T6 Ga/Gb
  • CS (Korea)
    • 12-KB4B0-0116X
      Ex ia IIC T6…T2
  • EAC (Eurasian Union)
    • RU C-DE.HA65.B.01093/21
      0Ex ia IIC T6..T2 Ga X
  • CE-Marking
    • ATEX-Directive 2014/34/EU
    • PED Directive 2014/68/EU
  • Material certificates 3.1, 3.2 acc. DIN EN10204:2004
  • Metrology (Custody Transfer)
    • OIML R117
      Liquids other than water (EU Type Approval)
  • Marine
    • DNV
    • ABS

Datasheet

application/pdf; charset=binary

TMU_2G_DB_25.01_en

1,6 MB
open download

Operating manual

application/pdf; charset=binary

UMC4 + TMU-W – EN

4,9 MB
open download
application/pdf; charset=binary

UMC3 + TMU – EN

4,5 MB
open download

Supplementary Operating Manual

application/pdf; charset=binary

TMx-EX_NA_BA_21.01_01

TM, TMU, TM-SH

1,0 MB
open download
application/pdf; charset=binary

TMx + UMC4 – EN

2,8 MB
open download
application/pdf; charset=binary

UMC3 – EN

1,7 MB
open download

Certificates and approvals

application/pdf; charset=binary

ABS_Corioils_PDA

497 KB
open download
application/pdf; charset=binary

ATEX – EN

5,7 MB
open download
application/pdf; charset=binary

GB-1659-Parts-Certificate

1,0 MB
open download
application/pdf; charset=binary

GYJ22.1873X_TM

NEPSI GYJ22.1873X

8,8 MB
open download
application/pdf; charset=binary

IECEx

1,3 MB
open download
application/pdf; charset=binary

TAA00002CD-revision2

DNV

228 KB
open download

Matching accessories

image UMC4

UMC4

Critical Flow Precision with UMC4 Transmitter

image UMC4-RM

UMC4-RM

Critical Flow Precision with UMC4 Transmitter in rack mount housing

image UMC3

UMC3

Transmitter for Coriolis Mass Flow Meter

Other Members of the KOBOLD group

Logo-KOBOLD.png
Logo-Henschen.jpg
Logo-Mesura.jpg
Logo-Unirota.png
Products by Keyword

Heinrichs Messtechnik GmbH

Robert-Perthel-Straße 9
50739 Köln

Tel.: +49 (221) 49708-0
Fax: +49 (221) 49708-178

Please activate JavaScript

A strong group ensures our availability on site – worldwide.

Member of the KOBOLD GROUP
www.kobold.com

linkedin.png youtube.png

Sizing

  • Variable Area
  • Coriolis Mass Flow Meter
  • Vortex flow meter
  • Imprint
  • Privacy Policy
  • General Terms & Conditions
  • Cookies & Features

All rights reserved

© Heinrichs Messtechnik GmbH

Heinrichs Messtechnik GmbH

Robert-Perthel-Straße 9
50739 Köln
Germany

+49 (0)221-497 08-0
+49 (221) 49708-178
Please activate JavaScript

Cookies & Features

This website uses cookies to provide content and features. Details of the technologies used can be found in our privacy policy.

Essential Cookies

Session data such as language selection or spam protection - you can't do without it.

Analytics
Google
· Imprint · Privacy Policy ·
loading
loading